Remote Linux Scan is Stuck at Collecting System Characteristics
Remote Linux Scan is Stuck at Collecting System Characteristics
Product Name
CIS-CAT Pro Assessor v4
Product Version
All
Date
Mar 23, 2022
Problem
I am unable to complete a remote Linux scan. The scan is getting stuck Collecting System Characteristics every time. The assessor-cli.log shows this error: RemoteExecSession --> Error initializing Sftp channel
Solution
Allow SFTP connections to be established between the CIS-CAT host and target. SFTP is required for remote Linux assessments. There is no workaround, other than performing a local Linux assessment.
SFTP uses port 22 by default
Keywords; Linux SFTP